Home >> Yueqing Tar Automation Equipment Co.,Ltd.
IP68 Waterproof Connector
Aviation waterproof connector
Industrial remote control
Electric valve
- SEV2000 (electric two-way valve)
- SEV3000 (electric ball valve)
- SEV4000 (electric valve)
- SEV5000 (electric ball valve)
- SEV7000 (electric valve)
- SEV8000 electric ball valve (manual function)
- SEV8000-1(Manual function)
- SEV8000 electric ball valve (manual function)
- SEV301 (electric ball valve)
- SEV501 (electric ball valve)
- SEV1200 actuator
- BV1703 series manual automatic integrated electric ball valve
- BV1701
- TV40 Electric Disc Valve
- TV50 electric ball valve
- TV60 (liquid crystal digital thermostatic valve)
- TV90 series electric valve (automatic reset)
- A8012 actuator
- A8088 actuator
- IS50 (Smart Card Locking Valve)
- MDEV30 (dynamic balancing electric valve)
- WL-601 wireless electric valve
- M-BUS Thermostatic valve
- MDEV10 (dynamic balancing electric valve)
- MDEV20 (Dynamic Balanced Electric Valve)
- EA10 (Electrothermal Actuator)
- EA20 (electric actuator)
- EA30 (electric actuator)
Thermostat
- MW-60 Mixed Water Thermostat
- FS60 (fan three speed switch)
- MT05 (Mechanical Thermostat)
- MT01 (Fan Coil Mechanical Thermostat)
- MT02 (Fan Coil Mechanical Thermostat)
- ET06 (fan coil electronic thermostat)
- ET30 (floor heating electronic thermostat)
- WL-601 Heating Internet Temperature Control
- DC50 LCD Thermostat
- DC80 LCD fresh air system thermostat
- HT50 LCD Thermostat
Waterproof Junction Box
Switching Power Supply
- Single output power supply --S series
- Dual output power supply --D series
- Din Rail Switching power supply --DR series
- Slim and seriesslim and series --HS Series
- Waterproof Power Supply -- LPV series
- Mini size switching power supply --MS Series
- Triple Output Switching power supply --T series
- Quad Output Switching power supply --Q Series
Wire Connector
Hand Crimping Tools

S-120

Model | S-120-5 | S-120-12 | S-120-15 | S-120-18 | S-120-24 | S-120-36 | S-120-48 |
DC output,current | 5V 24A | 12V 10A | 15V 8A | 18V 6.7A | 24V 5A | 36V 3.3A | 48V 2.5A |
Wave and noise | 50mvp-p | 50mvp-p | 75mvp-p | 75mvp-p | 75mvp-p | 120mvp-p | 120mvp-p |
Inlet stability | ±0.5% | ±0.3% | ±03% | ±0.2% | ±0.2% | ±0.2% | ±0.2% |
Load stability | ±0.5% | ±0.3% | ±03% | ±0.2% | ±0.2% | ±0.2% | ±0.2% |
Efficiency | 83% | 84% | 84% | 84% | 86% | 86% | 86% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% |
Input current | 3A/110V 1.5A/230VAC | ||||||
AC input voltage range | 85~132VAC , 47~63Hz , 240~370VDC | ||||||
AC Inrush current | Cold-start current 18A/115VAC 36A/230V | ||||||
Overload protection | 105%-130% Type: cut output; Reset: automatic recovery | ||||||
Over-voltage protection | 115%~135% | ||||||
Setup, rise, hold up time | 1s,100ms,20ms | ||||||
Withstand voltage | I/P-O/P: 1.5KVAC; I/P-F/G: 1.5KVAC; O/P-F/G: 0.5KVAC (1 Min) | ||||||
Isolation resistance | I/P-O/P, I/P-F/G, O/P-F/G, 500VDC/100MΩ | ||||||
Working temperature and humidity | `-10°C~+60°C, 20%~90%RH | ||||||
Safety standards | GB4943 UL60950 EN60950 | ||||||
EMC standards | GB9254 EN55022 ClassB | ||||||
Overall dimension | 199X98X38mm | ||||||
Weight | 0.62kgS |
Next:S-145