Home >> Yueqing Tar Automation Equipment Co.,Ltd.
点击这里给我发消息
Products Location:Home >>Products >> Products
T-50
Model T-50A T-50B T-50C T-50D
CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC output voltag current 5V  7A 12V  1A `-5V 1A 5V  5A 12V  1A -12V 1A 5V  4A 15V 1A `-15V  1A 5V  3A 12V 1A 24V 1A
Waave and noise 50mVp-p 100mVp-p 50mVp-p 50mVp-p 100mVp-p 100mVp-p 50mVp-p 100mVp-p 100mVp-p 50mVp-p 100mVp-p 100mVp-p
lnlet srability ±0.5% ±1% ±1% ±1% ±0.5% ±1% ±0.5% ±1% ±1% ±1% ±0.5% ±1%
Load stability ±0.5% ±5% ±5% ±6% ±0.5% ±0.5% ±0.5% ±5% ±5% ±6% ±0.5% ±5%
Efficiency 78% 79% 79% 80%
Adjustable range for DC voltage CH;+10,-5% CH;+10,-5% CH;+10,-5% CH;+10,-5%
AC input voltage range 85~132VAC/170~264VAC selected by switch 47~63Hz, 240~370VDC
input Current 2.0A/110V  1.0A/230VAC
AC input Currrent Cold-start current  35A/230V
Overioad proctecton 105%-135%     Type: cut output;   Reset: automatic recovery
Over-voltage protection CH1:115%-135%
Setup, rise, hold up time 200ms,100ms,30ms
Withstand voltage Input and output internal:1.5KVAC,Input and enclosure:l.5KVAC,Output and enclosure:0.5KVAC   1minute
Isolation resistance Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ
Working temperature and humidity `-10°C~+60°C(Refer to output derating curve),20%~90%RH
Safety standards GB9434  UL60950 EN60950
EMC standards GB9254  EN55022  ClassA
Overall dimension 159X98X38mm
Weight 0.55kgS